Parameter |
Description
|
Lead section
|
name |
Name of power station
|
name_official |
Official name, if different from name. Preferably in native language.
|
image |
Image filename, without File: parameter.
|
image_size |
Avoid using: Overrides the default 250px
|
image_caption |
Caption beneath image
|
image_alt |
Alternative text for image.
|
location_map |
Name of a location map file. The coordinates must be specified as well (see below).
|
location_map_size |
Avoid using: Overrides the default 250px
|
location_map_caption |
Caption beneath the location map
|
location_map_alt |
Alternative text for location map.
|
lat_d |
Latitude degrees.
|
lat_m |
Latitude minutes. Omit or leave blank if lat_d is in decimal format.
|
lat_s |
Latitude seconds. Omit or leave blank if lat_d is in decimal format. Remember to avoid being overly precise.
|
lat_NS |
Northern or Southern latitude (enter N or S ). Omit or leave blank if lat_d is in decimal format.
|
long_d |
Longitude degrees.
|
long_m |
Longitude minutes. Omit or leave blank if long_d is in decimal format.
|
long_s |
Longitude seconds. Omit or leave blank if long_d is in decimal format. Remember to avoid being overly precise.
|
long_EW |
Longitude East or West (enter E or W ). Omit or leave blank if long_d is in decimal format.
|
coordinates_type |
Optional parameter to add additional coordinate functions. See here for more details.
|
coordinates_display |
Display the coordinates inline or title, or both as inline,title.
|
country |
Country where the facility is located. Do not use flag icons, as this places an unnecessary emphasis on nationality; see MOS:FLAG for a detailed rationale.
|
location |
General area where located. Avoid being overly-detailed.
|
status |
State of the project. Enter any one of the following auto-expanding fields: P =Proposed, U =Under construction, O =Operational, M =Mothballed, D =Decommissioned.
|
construction_began |
Date construction of the first unit began, consider using {{Start date}}.
|
commissioned |
Date commissioned, or to be commissioned, of the first unit. Consider using {{Start date}}.
|
decommissioned |
Date decommissioned, or to be decommissioned, of the last unit. Consider using {{End date}}.
|
cost |
Total cost of development
|
owner |
Owner(s) of the power station. Consider limiting to the top two, and include ownership percentage. Example: Owner1: 60% <br/>Owner2: 40%
|
operator |
Plant operator(s). If different from owner.
|
Geothermal power stations
|
geo_type |
The type of geothermal power station. Enter any one of the following auto-expanding fields: DS =Dry steam, FS =Flash steam, BC =Binary cycle.
|
geo_temp_requirement |
Minimum temperature requirement of geothermal source. Consider using: {{Convert|XX|C|F|0|abbr=on}}
|
geo_well_count |
Number of geothermal wells.
|
geo_well_depth |
Depth of the deepest well.
|
geo_water_output |
Hot water production in litres.
|
Nuclear power stations
|
nuke_reactor_type |
The type(s) of reactors currently in use, and its corresponding number of reactors. For multiple reactors types, you may use the <br/> function. For power stations using a single type of reactor, enter any one of the following auto-expanding fields: PWR =PWR, BWR =BWR, PHWR =PHWR, RBMK =RBMK, GCR =GCR, AGR =AGR, FBR =FBR, PBR =PBR, MSR =MSR, AHR =AHR.
|
nuke_reactor_supplier |
Reactor supplier(s)
|
nuke_fuel_type |
Type of nuclear fuel.
|
nuke_fuel_supplier |
Supplier of nuclear fuel.
|
nuke_water_source |
Source of cooling water.
|
nuke_water_distance |
Distance from source of cooling water.
|
nuke_cooling_towers |
Number of cooling towers.
|
Pumped-storage hydroelectric power stations
|
psps_upper_res |
Name of upper reservoir.
|
psps_upper_res_capacity |
Water storage capacity of upper reservoir.
|
psps_penstocks |
Number of penstocks between the reservoirs.
|
psps_lower_res |
Name of lower reservoir.
|
psps_lower_res_capacity |
Water capacity of lower reservoir.
|
psps_hydraulic_head |
Hydraulic head from upper reservoir.
|
psps_generators |
Number of generation units of the pumped-storage power station.
|
psps_pumpgenerators |
Number of units used for both generating and pumping.
|
psps_pumps |
Number of pumping units to the upper reservoir.
|
Solar farms
|
solar_type |
The type of solar technology in use. Enter any one of the following auto-expanding fields: PV =Flat-panel PV, CPV =CPV, CSP =CSP
|
solar_cpv_concentration |
Concentration of CPV plant: Low , Medium , or High . See also: Types of CPV.
|
solar_csp_technology |
The CSP technology in use. Enter any one of the following auto-expanding fields: D =Dish Stirling, T =Solar power tower, F =Fresnel reflector, or P =parabolic trough.
|
solar_csp_heliostats |
Number of heliostats.
|
solar_cpvt |
Is the power station a CPVT type? Add Yes or No .
|
solar_site_area |
Land area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
|
Tidal power stations
|
tide_technology |
The tidal technology in use. Enter any one of the following auto-expanding fields. For tidal barrage technology, please use infobox dam. TSG =Tidal stream generator, DTP =Dynamic tidal power
|
tide_tsg_type |
Type of tidal stream generator.
|
tide_barrage_height |
Height of tidal barrage.
|
tide_barrage_length |
Length of tidal barrage.
|
tide_barrage_width |
Width of tidal barrage.
|
tide_crosses |
Channel of water across which the barrage is build, or in which the tidal generators are located.
|
tide_channel_width |
Width of above mentioned channel.
|
tide_channel_speed |
Speed of water flow in the above mentioned channel. Consider using: {{Convert|XX|m/s|ft/s|1|abbr=on}}
|
tide_dtp_length_perp |
Perpendicular length of the dynamic tidal power structure.
|
tide_dtp_length_para |
Parallel length of the dynamic tidal power structure.
|
tide_range |
Tidal range created by the dynamic tidal power structure.
|
Wave farms
|
wave_technology |
The wave technology in use (capture method). Capture methods are buoy (point absorber), surface-following attenuator, terminator, oriented perpendicular to the direction of wave propagation, oscillating water column, underwater attenuator.
|
wave_site_area |
Surface area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
|
wave_generator_depth |
Average water depth at the converter locations. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
|
wave_shore_distance |
Minimum distance from shore of wave farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
|
Wind farms
|
wind_farm_type |
Type of wind farm (Onshore, Nearshore, Offshore). See also Types of wind farms.
|
wind_site_elevation |
Highest ground altitude (don't add hub height) over which a turbine is constructed. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
|
wind_site_usage |
Ground usage of Onshore wind farms (e.g. Farm land, desert, etc).
|
wind_site_area |
Area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
|
wind_offshore_depth |
Average water depth of Offshore wind farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
|
wind_offshore_distance |
Minimum distance from shore of Offshore wind farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
|
wind_hub_height |
Height of the wind turbine towers from base to hub. Consider using: {{Convert|XX|m|ft|0|abbr=on}} If multiple types of turbines are in use, enter the maximum value.
|
wind_rotor_diameter |
Diameter of wind turbine rotor. Consider using: {{Convert|XX|m|ft|0|abbr=on}} If multiple types of turbines are in use, enter the maximum value.
|
wind_rated_speed |
Rated wind speed of the wind turbine model. Consider using: {{Convert|XX|m/s|ft/s|1|abbr=on}} If multiple types of turbines are in use, enter the minimum value.
|
End section (used by all power station types, including those not listed above)
|
ps_fuel_primary |
Primary fuel source
|
ps_fuel_secondary |
Secondary fuel source (optional)
|
ps_fuel_tertiary |
Tertiary fuel source (optional)
|
ps_units_operational |
Number of currently operational turbines/generating units. Not applicable for pumped-storage power stations.
|
ps_units_manu_model |
Shortened name(s) of manufacturers and models of currently operational turbines/generating units.
|
ps_units_uc |
Number of generating units under construction.
|
ps_units_planned |
Number of generating units currently planned/proposed for installation.
|
ps_units_decommissioned |
Number of generating units decommissioned.
|
ps_electrical_capacity |
Current gross installed capacity in megawatts.
|
ps_electrical_cap_fac |
Capacity factor of the power station, in percentage.
|
ps_thermal_capacity |
Thermal capacity.
|
ps_annual_generation |
Average annual gross power generation of the previous whole year.
|
ps_cogeneration |
Is the power station a cogeneration type? Add Yes or No .
|
ps_combined_cycle |
Is the power station a combined cycle type? Add Yes or No .
|
website |
Official website.
|
extra |
Use this field to add an additional infobox within this infobox.
|